Automated Liquid Handling System PANAS401

- Tianlong
- China
- 1-2 weeks
- 50 units/M
Tianlong PANA S401/S201 Automated Pipetting Workstation is designed as an important tool for PCR Setup, which automates tedious, error-prone manual tasks and provides consistent sample mixing and excellent pipetting performance to standardize your results. Tianlong PANA S401/S201 Automated Pipetting Workstation together with the automated nucleic acid extractor and real-time PCR system, a fully automated, high-throughput, and standardized process of nucleic acid detection can be realized in your lab.
Automated Liquid Handling System |
Product Features |
Precise PCR Setup 2 and 4 channel options, up to 768 samples per setup, PANA S401 supporting 96 samples within 10min Standardized procedures Provide consistent sample mixing and excellent pipetting performance to standardize your results Highly compatible with various PCR kits Compatible with regular PCR tubes, PCR strip tubes and PCR plates (up to 384- well x 2) Excellent anti-contamination measures Minimized contamination measures like directional exhaust with HEPA filters, internal negative pressure system Optimized efficiency Starting preparation programs with just one click, multiple setups for different tests in one run |
Parameters | ||
Model | PANA S401 (Pro) | PANA S201 (Standard) |
Sample Loading Channels | 4 loading channels | 2 loading channels |
Throughput | 96 samples; up to 768 samples per one go | |
Pipetting Volume | 1-1000μL | |
Tip Volume | 5-50μL; 50-1000μL | |
Performance | Below 15μL: accuracy: A<2%, repeatability: CV<5.0% 15μL-50μL: accuracy: A<1.5%, repeatability: CV<1.5% Above 50μL: accuracy: A<1.0%, repeatability: CV<1.2% | |
Liquid Level Detection | Pressure-sensing level detection; aspiration with the liquid level to ensure accuracy | |
Compatible Consumables | Compatible with 0.1mL/0.2mL 8-tube strips, 96-well and 384-well PCR plates | |
Operating System | Windows 10 Pro Edition, bilingual interface in Chinese/English | |
Connectivity | USB port, RS252 port | |
Overall Size | 860mm(L)x735mm(W)x746mm(H) | |
Instrument Weight | 100kg (net) | |
Operating Environment | Temperature: 15°C-35°C; humidity: <70% | |
Power Supply | AC 220V; 50Hz |
1.1 Sample throughout difference: Gentier96 can process maximum 96 samples per run, Gentier48 can process maximum 48 samples per run; 1.2 Fluorescence channel difference: Gentier96 E/R has 6/4 fluorescence channels separately, Gentier48 E/R has 4/2 fluorescence channels; 1.3 Light source location difference : The light source of Gentier96 is on the top, which requir...more