Human Cytomegalovirus (HCMV) Nucleic Acid Detection Kit

- Tian Long
- China
- 1-2 weeks
- 500000 Test/M
The Tianlong Human Cytomegalovirus (HCMV) Nucleic Acid Detection Kit is an in vitro polymerase chain reaction (PCR) assay for the quantitative detection of human cytomegalovirus (HCMV) DNA in human urine sample.
Description:
HCMV is a common virus that remains dormant in healthy individuals. In immunocompromised patients, HCMV can lead to serious complications. Precise and timely quantitation of HCMV in critically ill patients is important to guide preemptive strategies for disease prevention, diagnose onset of condition, monitor response to therapy, and detect reactivation of latent virus.The results from the test must be interpreted within the context of all relevant clinical and laboratory findings. It is not intended as a screening test for the presence of HCMV DNA.
Tianlong Human Cytomegalovirus (HCMV) Nucleic Acid Detection Kit is an in vitro polymerase chain reaction (PCR) assay for the quantitative detection of human cytomegalovirus (HCMV) DNA in human urine sample.
Product Features:
Traceability to the WHO Standard
Precise and fully traceable quantification according to 1st WHO International Standard for Human Cytomegalovirus for Nucleic Acid Amplification Techniques(NIBSC 09/162)
HCMV Viral Load Monitoring
Detection and quantification of Human Cytomegalovirus (HCMV) DNA, enabling a common strategy to be developed in the management of HCMV infection and help in clinical decision making
Accurate HCMV Viral Load Quantification
Accurate HCMV viral load quantification over a broad linear range from 1.0 × 103 copies/mL to 1.0 × 108 copies/mL
Internal Control
The use of internal control system in the kit can effectively prevent false negative results
Good Compatibility
Widely applicable in instruments with FAM, VIC (HEX) fluorescence channels
Product Order Info.:
Product Name | Human CytomegaloVirus (HCMV) Nucleic Acid Detection Kit (Fluorescence PCR Method) |
Cat.No | P107H |
Specification | 32T/kit |
Specimen | Urine sample |
Linear range | 1.0 × 103 copies/mL ~ 1 × 108 copies/mL |
LOD | 500 copies/mL |
Precision | ≤5% |
Storage & Validity | -25℃~-15℃ for 12 months |
Applicable Equipment | Instruments with FAM, VIC (HEX) fluorescence channels such as Tianlong Gentier Real-time PCR Systems, ABI7500 real time PCR systems |
1.1 Sample throughout difference: Gentier96 can process maximum 96 samples per run, Gentier48 can process maximum 48 samples per run; 1.2 Fluorescence channel difference: Gentier96 E/R has 6/4 fluorescence channels separately, Gentier48 E/R has 4/2 fluorescence channels; 1.3 Light source location difference : The light source of Gentier96 is on the top, which requir...more